LOG100/200 - Logic Analyzer 200 MS/s 16 or 32 Channels, 32KB/Channel
- ISA Logic-Analyzer Card
- This Logic-Analyzer is also available as 200 M/S Desktop PCI Logic-Analyzer
- 200 MHz timing analysis on 16 channels ( doubled memory )
- 100 MHz - 250 Hz timing analysis on 32 channels
- 50 MHz state analysis on all channels
- External clock / BNC input or predefined clock terms usable ( i.e. (/CH0 + /CH1) * CH2 * CH3 )
- Software for Windows 2000/NT and ME/98/95
- Hardware downloadable via software upate ( LCA )
- 5 years warranty
|
| Sorry, but this product is no longer available. You still can get updated manuals and drivers from this website and can contact us if you have any problems with your product.
| |
The LOG200/100 is our high end Logic-Analyzer that makes it possible to read up to 200MS/sec on 16 channels or 100MS/s or less with 32 channels. Equipped with a professional Windows Software this board changes your PC into a highgraded measuring system. The LOG200/100 samples at 100Mhz across all 32 channels with no speed and channel trade offs. With 200 Mhz the channel count is reduced to 16 input channels. In this mode the memory depth is doubled.
Most time logic analyzer have had a bad reputation of being difficult to setup and use. QUANCOM has spent a significant amount of time developing a user interface that is intuitive and easy to use. First time users should easily learn the overall system within 1 hour. Signal names can be quickly defined with the option of grouping them into busses or as individual signals. Waveform navigation is very simple with high speed scrolling, and three timing cursors are easy to place with a click of the mouse button. All parameter settings and waveform settings can be saved to disk and quickly recalled later.
|
Technical Data
|
•Inputs
|
Number of Channels: 16 / 32
Max. Sampling rate: 200 MS/s / 100MS/s
Memory Depth per Channel: 32768 Bytes
Triggering on level: 0 (low), 1 (high), X (don´t care)
Pretrigger: 1/8, 2/8, 3/8, 4/8, 5/8, 6/8, 7/8 before the adjusted trigger word
Additionally,an external clock can also be attached via a BNC-Input.
The Channels 0 - 3 are mutually independently invertible for an external clock
|  |
•Bus
|
02B0, 0300, 0310, 0330, 0390, 03B0, 03E0
|  |
•Default I/O
|
0390
|  |
•Connectors/Bracket
|
37pin D-Sub Connector (female), BNC Connector
|  |
•CE
|
Ja
|  |
•Internal Timebase
|
100 MHz
|  |
•Temperature Range
|
0...50 °C
|  |
Additional information
|
•Description
|
New generation of LA's The new QUANCOM logic analyzers are high-quality logic analyzers with an optimal prizing and power ratio. The generation of Logic-Analyzer developed again consists of four versions, that allows sampling speeds up to 200MS/s and a number of channels up to 32 channels. The software Logic-Analyze is contained in scope of delivery and allows a very convenient metering among Windows.
High sampling speed The top model LOG100/200 can sample up to 200MS/s on 16 channels simultaneous. At a sampling speed of 100MS/s or lower, 32 channels are available to the customer. The variant LOG50/100 achieves 100MS/s with 16 channels or 50MS/s or lower with 32 channels. The models LOG50 and LOG100 sample up to 50MS/s or 100MSamples/sec with 32 channels.
Amplifier Reasonable extended are the Logic Analyzer with the OPTION, to measure directly on the object. The combination is set up by the amplifier with test leads (30cm) to the object of measurement. In this case, signals are amplified and can be measured at a distance of 1m+0,3m from the PC. Supplied is a 16-channel amplifier module that is tested on ELECTROMAGNETIC COMPATIBILITY with the cable.
Channels+Memory depth 32 TTL inputs (32768 Bit/Channel)
Speed Samplingspeed: 200MHz*,100MHz*,50MHz,25MHz,10MHz,5MHz,2.5MHz,1MHz,500kHz,250kHz, 100kHz,50kHz,25kHz,10kHz,5kHz,2.5kHz,1kHz,500Hz,250Hz,external clock(**)
(*) is version dependent
(**)Sampling on the raising and/or falling edge:
STATE-CLOCK = K0 * BNC STATE-CLOCK = (K0 * K1)* BNC STATE-CLOCK = K0 * K1 * K2 * BNC STATE-CLOCK = (K0 + K1) * BNC STATE-CLOCK = (K0 + K1) * K2 * BNC (e.g., check spy 80x86 IO port accesses (IOR + IOW) * /AEN ) STATE-CLOCK = (K0 + K1 + K2) * BNC STATE-CLOCK = (K0 + K1 + K2 + K3) * BNC STATE-CLOCK = (K0 * K3) * BNC STATE-CLOCK = K0 * K1 * K3 * BNC STATE-CLOCK = K0 * K1 * K2 * K3 * BNC STATE-CLOCK = (K0 + K1) * K2 * K3 * BNC STATE-CLOCK = (K0 + K1 + K2)* K3 * BNC STATE-CLOCK = (K0 + K1 + K2)* K3 * BNC
You have the possibility to connect an external Clock over the BNC socket. Furthermore, you can invert every channel (channel 0-3 and BNC) individualy.
Triggering Triggering to 0 (low), 1 (high), X (don't care) Trigger on all 32 Channels Triggerering after n-Events Triggering at events with one defaulted minimum pulse width and/or maximum pulse width. Pretrigger 1/8,2/8,3/8,4/8,5/8,6/8,7/8 the capacity before adjusted Triggerword in the case of 200MS/s: 2/8,4/8,6/8.
Software Simple application program for Windows 3.x and Windows 95 with state and timing representation. Windows NT 4.x software included as beta release (free update assurance via E-Mail or our homepage at http://www.quancom.de). Loading and storage of the configuration and of the recorded data.High quality printing on B&W printer or color printer. Copying data to clipboard for later processing in other Windows programs. ·Free assignment of the timing channels, assignment of the bit's for the state channels · Display Hex, Dec, Oct, Bin and freely definable symbols (label or bit manner). Searching and marking function. and others
Free evaluationcopy you further find below on this page, a cross reference to software Logic-Analyze 2.0, where you can download the evaluation copy.
Other all QUANCOM logic analyzers are as PC-Cards for the ISA bus designed. Recording e.g. then occurs if the trigger condition was 12 times valid or the adjusted trigger condition was at least 180 ns valid. Both can also be combined. The corresponding Windows program offers state or timing representation and makes the selection of one or several channels possible in addition to many further functions as a trigger condition, in the set-up, the hardware fit in each case can be adjusted. Over a 37-pole D-SUB socket which is available at the slot shield, the LOG-KAB (Logic cord) can be connected.
We recommend the effort of our amplifiers LOGAMV1 and LOGAMV2. as a reasonable accessory We offer test prods for a comfortable metering, directly to IC'S (micro-Kleps).
|  |